Method development and validation of anti-histaminic drug in plasma (Paperback)

, ,
A selective, rapid and sensitive reverse phase ultra- performance liquid chromatography method was developed for the quantitative determination of fexofenadine in human plasma. With carbamazepine as internal standard, sample pretreatment involved a one-step extraction with ethyl acetate from 980 l plasma. The sample was analyzed using 10mM KH2PO4 buffer pH 2.5 and acetonitrile (70:30 v/v) as mobile phase. Chromatographic separation was achieved on an ACQUITY UPLC BEH (C-18) column using isocratic elution. The peak was detected using UV-PDA detector set at 210 nm and the total time for chromatographic separation was 10 min. Linear calibration curves were obtained in the concentration range of 30.09-1805.39 ng/ml with a lower limit of quantification of 30.09 ng/ml. The inter and intra- day precision (RSD) values were below 15% and accuracy (RE) was from 1.55 to 5.51 % at all QC levels. Developed method was found to be accurate, precise, selective and rapid for estimation of fexofenadine in plasma and can be used for pharmacokinetic and bioequivalence studies.

R1,304

Or split into 4x interest-free payments of 25% on orders over R50
Learn more

Discovery Miles13040
Mobicred@R122pm x 12* Mobicred Info
Free Delivery
Delivery AdviceShips in 10 - 15 working days


Toggle WishListAdd to wish list
Review this Item

Product Description

A selective, rapid and sensitive reverse phase ultra- performance liquid chromatography method was developed for the quantitative determination of fexofenadine in human plasma. With carbamazepine as internal standard, sample pretreatment involved a one-step extraction with ethyl acetate from 980 l plasma. The sample was analyzed using 10mM KH2PO4 buffer pH 2.5 and acetonitrile (70:30 v/v) as mobile phase. Chromatographic separation was achieved on an ACQUITY UPLC BEH (C-18) column using isocratic elution. The peak was detected using UV-PDA detector set at 210 nm and the total time for chromatographic separation was 10 min. Linear calibration curves were obtained in the concentration range of 30.09-1805.39 ng/ml with a lower limit of quantification of 30.09 ng/ml. The inter and intra- day precision (RSD) values were below 15% and accuracy (RE) was from 1.55 to 5.51 % at all QC levels. Developed method was found to be accurate, precise, selective and rapid for estimation of fexofenadine in plasma and can be used for pharmacokinetic and bioequivalence studies.

Customer Reviews

No reviews or ratings yet - be the first to create one!

Product Details

General

Imprint

VDM Verlag

Country of origin

Germany

Release date

August 2011

Availability

Expected to ship within 10 - 15 working days

First published

August 2011

Authors

, ,

Dimensions

229 x 152 x 5mm (L x W x T)

Format

Paperback - Trade

Pages

76

ISBN-13

978-3-639-37782-8

Barcode

9783639377828

Categories

LSN

3-639-37782-6



Trending On Loot